CESP Microcontroller Programmable Automatic Lubricator
You can set to the desired rest interval and pump activation to fit your application exactly.
Pump activation time is adjustable by DIP switch (Red one on the left) .
Available settings are 2, 3, 5, 10, 15, 20, 25, 30 seconds
Refer to the diagram under the cover (see photo) for settings.
For example, the red DIP switch on the left set at "000" means 2 second activation time, and "111" means 30 second activation time.
Rest interval is adjustable by DIP switch (Blue one on the right).
Available settings are 3, 5, 10, 15, 20, 30, 60 and 180 minutes.
Refer to the diagram under the cover (see photo) for settings.
For example, the blue DIP switch on the right set at "000" means 3 minute interval time, and "111" means 180 minute interval time.
Note: The 3rd DIP switch determines whether the unit pumps immediately upon start up or wait until rest interval has passed.
Force feed button on front panel.
Buzzer alarm for low lubrication warning as well as output terminal.
There is a wiring diagram on the case cover.
CHEN YING brand, Made in Taiwan.
This unit is very popular for high precision CNC machines.
If you have any questions please don’t hesitate to contact us, we’ll be happy to help.